Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.565
Filtrar
1.
J Surg Res ; 276: 283-290, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35405414

RESUMO

INTRODUCTION: The magnetic compression technique (MCT) is used for the anastomosis of hollow organs by the means of suction between magnets. The MCT is useful for establishing digestive tract anastomoses in rats, for example, end-to-side small intestinal anastomosis and colonic anastomosis. We aim to determine the feasibility of MCT-based esophageal anastomosis in rats. METHODS: Twenty-four Sprague-Dawley albino rats (230-250 g) were randomly divided into an MCT group and a control group (hand-sewn esophageal anastomosis). The time required to construct the anastomosis, postoperative complications, and survival rate was compared between the two groups. At 2 wk postoperatively, the animals were sacrificed to assess the burst pressure and histological features of the anastomoses. RESULTS: The mean anastomosis time was significantly lower for MCT (11.17 ± 1.64 min) than for the hand-sewn technique (27.42 ± 2.23 min; P < 0.001). The survival rate was slightly higher in the MCT group (91.67%) than in the control group (66.67%, P = 0.317). The magnets were discharged from the body after 8.33 ± 0.89 d (range, 7-10 d). No anastomotic leakage or stenosis occurred in the MCT group. Three rats developed anastomotic stenosis and two rats developed anastomotic leakage in the control group. The burst pressures were similar in the two groups. An histological examination showed that compared with the control group, the MCT group had better alignment of the tissue layers and less inflammation. CONCLUSIONS: The MCT is a simple and feasible technique for esophageal anastomosis in rats and has the potential for clinical application.


Assuntos
Anastomose Cirúrgica , Procedimentos Cirúrgicos do Sistema Digestório , Esôfago , Imãs , Anastomose Cirúrgica/efeitos adversos , Anastomose Cirúrgica/instrumentação , Anastomose Cirúrgica/métodos , Fístula Anastomótica/etiologia , Fístula Anastomótica/prevenção & controle , Animais , Constrição Patológica/etiologia , Procedimentos Cirúrgicos do Sistema Digestório/efeitos adversos , Procedimentos Cirúrgicos do Sistema Digestório/instrumentação , Procedimentos Cirúrgicos do Sistema Digestório/métodos , Esôfago/cirurgia , Fenômenos Magnéticos , Ratos , Ratos Sprague-Dawley , Técnicas de Sutura
2.
Sci Robot ; 7(62): eabj2908, 2022 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-35080901

RESUMO

Autonomous robotic surgery has the potential to provide efficacy, safety, and consistency independent of individual surgeon's skill and experience. Autonomous anastomosis is a challenging soft-tissue surgery task because it requires intricate imaging, tissue tracking, and surgical planning techniques, as well as a precise execution via highly adaptable control strategies often in unstructured and deformable environments. In the laparoscopic setting, such surgeries are even more challenging because of the need for high maneuverability and repeatability under motion and vision constraints. Here we describe an enhanced autonomous strategy for laparoscopic soft tissue surgery and demonstrate robotic laparoscopic small bowel anastomosis in phantom and in vivo intestinal tissues. This enhanced autonomous strategy allows the operator to select among autonomously generated surgical plans and the robot executes a wide range of tasks independently. We then use our enhanced autonomous strategy to perform in vivo autonomous robotic laparoscopic surgery for intestinal anastomosis on porcine models over a 1-week survival period. We compared the anastomosis quality criteria-including needle placement corrections, suture spacing, suture bite size, completion time, lumen patency, and leak pressure-of the developed autonomous system, manual laparoscopic surgery, and robot-assisted surgery (RAS). Data from a phantom model indicate that our system outperforms expert surgeons' manual technique and RAS technique in terms of consistency and accuracy. This was also replicated in the in vivo model. These results demonstrate that surgical robots exhibiting high levels of autonomy have the potential to improve consistency, patient outcomes, and access to a standard surgical technique.


Assuntos
Anastomose Cirúrgica/métodos , Procedimentos Cirúrgicos do Sistema Digestório/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Algoritmos , Anastomose Cirúrgica/instrumentação , Anastomose Cirúrgica/estatística & dados numéricos , Animais , Procedimentos Cirúrgicos do Sistema Digestório/instrumentação , Procedimentos Cirúrgicos do Sistema Digestório/estatística & dados numéricos , Humanos , Intestino Delgado/cirurgia , Laparoscopia/instrumentação , Laparoscopia/métodos , Laparoscopia/estatística & dados numéricos , Aprendizado de Máquina , Movimento (Física) , Imagens de Fantasmas , Procedimentos Cirúrgicos Robóticos/instrumentação , Procedimentos Cirúrgicos Robóticos/estatística & dados numéricos , Técnicas de Sutura , Suínos
3.
J Hepatobiliary Pancreat Sci ; 29(7): 817-824, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35030302

RESUMO

BACKGROUND/PURPOSE: Although the lumen-apposing metal stent (LAMS) is useful for interventional endoscopic ultrasound (EUS) procedures, there has been some concern about the potential for stent-induced adverse events because of the high lumen-apposing force. A newly designed LAMS with less lumen-apposing force has been developed for use with a physician-controlled electrocautery-enhanced delivery system. The aim of this animal study was to evaluate the feasibility of performing interventional EUS using this newly designed LAMS system. METHODS: Endoscopic ultrasound-guided cystogastrostomy was performed using the novel LAMS three times in a wet simulation model. EUS-guided gastroenterostomy and EUS-guided gallbladder drainage were then performed using the system in four pigs. RESULTS: The LAMS was successfully placed in all three EUS-guided cystogastrostomy procedures using the wet simulation model and in all four EUS-guided gastroenterostomy and gallbladder drainage procedures in the animal model. In the 3 weeks following the procedure, eating behavior was normal in all animals and there were no adverse events. The stents remained patent during this time and were removed without difficulty. The fistula was mature in all cases and a standard upper gastrointestinal endoscope was easily advanced via the fistula to observe the afferent and efferent loops or the lumen of the gallbladder. Necropsy confirmed complete adhesion between the stomach and the wall of the jejunum or gallbladder. CONCLUSIONS: Our study findings demonstrate the feasibility of this new LAMS system and its potential clinical value for interventional EUS.


Assuntos
Anastomose Cirúrgica , Eletrocoagulação , Endossonografia , Implantação de Prótese , Stents , Ultrassonografia de Intervenção , Anastomose Cirúrgica/instrumentação , Anastomose Cirúrgica/métodos , Animais , Fístula do Sistema Digestório/etiologia , Fístula do Sistema Digestório/cirurgia , Drenagem/instrumentação , Drenagem/métodos , Eletrocoagulação/instrumentação , Eletrocoagulação/métodos , Endossonografia/instrumentação , Endossonografia/métodos , Vesícula Biliar/cirurgia , Jejuno/cirurgia , Modelos Animais , Implantação de Prótese/instrumentação , Implantação de Prótese/métodos , Estômago/cirurgia , Suínos , Ultrassonografia de Intervenção/instrumentação , Ultrassonografia de Intervenção/métodos
4.
Prenat Diagn ; 42(2): 164-171, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35048376

RESUMO

OBJECTIVES: To develop and test a novel vesicoamniotic shunt (VAS) to treat fetal lower urinary tract obstruction (LUTO), decrease dislodgement and optimize shunt deployment in-vitro. METHODS: Vesicoamniotic shunt design objectives included: (1) robust and atraumatic fixation elements, (2) kink resistant conduit to adjust to fetal movement and growth, (3) one-way pressure valve to facilitate bladder cycling, and (4) echogenic deployment visualization aids. The force to dislodge the novel Vortex shunt was compared with existing commercially available shunts in a bench-top porcine bladder model. Sonographic echogenicity was evaluated with ultrasound-guided deployment, and the shunt valve pressure measured. RESULTS: A prototype novel Vortex shunt was developed using braided nitinol "umbrella-type" ends with a kink-resistant stem incorporating an internal one-way valve. The peak force required to dislodge the Vortex shunt was significantly higher than commercially available shunts (p < 0.01). Shunt deployment in the bench-top model was easily confirmed with ultrasound guidance and the brisk decompression of the inflated porcine bladder thereafter. In-vitro valve gauge pressure testing mirrored bladder pressures in human LUTO cases. CONCLUSION: In-vitro testing shows that the Vortex shunt may improve deployment, sonographic visualization, kink resistance, and dynamic size adjustment. Validation in preclinical animal models are warranted and currently underway.


Assuntos
Desenho de Equipamento/métodos , Doenças Fetais/cirurgia , Terapias Fetais/instrumentação , Obstrução Uretral/cirurgia , Procedimentos Cirúrgicos Urológicos/instrumentação , Anastomose Cirúrgica/instrumentação , Anastomose Cirúrgica/métodos , Animais , Feminino , Terapias Fetais/métodos , Técnicas In Vitro , Gravidez , Suínos , Procedimentos Cirúrgicos Urológicos/métodos
5.
Dis Colon Rectum ; 65(2): 246-253, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34657080

RESUMO

BACKGROUND: The International Transanal Total Mesorectal Excision Registry group showed that transanal total mesorectal excision included clinical issues regarding anastomosis-related complications. OBJECTIVE: This study evaluated anastomotic complications in patients whose anastomoses were created with the stapler plus reinforced sutures procedure after transanal total mesorectal excision for low rectal cancer. DESIGN: This was a retrospective single-center study. SETTING: The study was conducted at the National Cancer Center Hospital East, Japan. PATIENTS: Between June 2016 and December 2019, 150 patients underwent transanal total mesorectal excision for low rectal cancer. Stapled anastomosis was performed for 55 patients, and coloanal handsewn anastomosis was performed for 95 patients. Blood perfusion of the colon was routinely evaluated with intraoperative indocyanine green fluorescence angiography. All patients who underwent stapled anastomosis received additional handsewn sutures on all rounds of the stapled line. Patients who underwent intersphincteric resection were excluded. MAIN OUTCOME MEASURES: The anastomosis-related complications were compared between the groups. RESULTS: Early anastomotic leakage was found in one (1.8%) and eight (8.4%) patients in the stapled group and handsewn group. Overall anastomosis-related complications, pelvic abscess, and anastomotic stenosis were significantly less frequent in the stapled group (p < 0.001, p < 0.048, and p < 0.032). Incomplete donuts after the stapled anastomosis were observed in 9 patients (16.4%); however, we reinforced all around the stapled line in these patients, and this reduced the subsequent occurrence of anastomotic leakage. LIMITATIONS: First, this was a retrospective single-center study that was not randomized or controlled. Second, there were chronological differences regarding the anastomotic method between the two groups. Third, our study included a relatively small number of patients who received preoperative chemoradiotherapy. CONCLUSIONS: Stapled anastomosis with reinforced handsewn sutures resulted in fewer anastomosis-related complications than did coloanal handsewn anastomosis after transanal total mesorectal excision for low rectal cancer; thus, the former may be superior and should be the preferred method, when technically possible. See Video Abstract at http://links.lww.com/DCR/B749.COMPLICACIONES RELACIONADAS CON LAS ANASTOMOSIS ENGRAMPADAS Y REFORZADAS CON SUTURAS EN LA EXCISIÓN TOTAL DEL MESORRECTO POR VÍA TRANSANAL EN CASOS DE CÁNCER DE RECTO BAJO: ESTUDIO RETROSPECTIVO UNICÉNTRICO. ANTECEDENTES: El grupo del Registro Internacional de Excisión Total del Mesorrecto por vía Transanal mostró que la excisión total mesorrectal transanal incluía problemas clínicos relacionados a las complicaciones involucradas con la anastomosis. OBJETIVO: Se evaluaron las complicaciones anastomóticas en pacientes cuyas anastomosis se realizaron con engrampadora reforzada de suturas después de la excisión total de l mesorrecto por vía transanal en casos de cáncer de recto bajo. DISEO: Estudio retrospectivo unicéntrico. AJUSTE: El Hospital del Centro Nacional del Cáncer del Este, Japón. PACIENTES: Entre junio de 2016 y diciembre de 2019, 150 pacientes se sometieron a excisión total del mesorrecto por vía transanal en casos de cáncer de recto bajo. Se realizó anastomosis con engrampadora en 55 y anastomosis coloanal suturada a mano en 95 pacientes. La perfusión tisular sanguínea del colon operado se evaluó de forma rutinaria con angiografía de fluorescencia con verde de indocianina intraoperatoria. Todos los pacientes que se sometieron a anastomosis con grapas recibieron suturas realizadas a mano adicionales sobre la totalidad de la línea de grapas. Se excluyeron los pacientes sometidos a resección interesfintérica. PRINCIPALES MEDIDAS DE RESULTADO: Las complicaciones relacionadas con la anastomosis se compararon entre los grupos. RESULTADOS: Se encontró fuga anastomótica temprana en 1 (1.8%) y 8 (8.4%) pacientes en el grupo de engrampado y en el grupo suturado a mano, respectivamente. En general, las complicaciones relacionadas con la anastomosis, el absceso pélvico y la estenosis anastomótica fueron significativamente menos frecuentes en el grupo con grapas (p < 0.001, p < 0.048, p < 0.032, respectivamente). Se observaron donas incompletas después de la anastomosis grapada en 9 pacientes (16,4%); sin embargo, reforzamos todo alrededor de la línea de grapas en estos pacientes, y esto redujo la aparición posterior de fugas anastomóticas. LIMITACIONES: Inicialmente, este fue un estudio retrospectivo de un solo centro que no fue aleatorizado ni controlado. En segundo lugar, hubo diferencias cronológicas con respecto al método anastomótico entre los dos grupos. En tercer lugar, nuestro estudio incluyó un número relativamente pequeño de pacientes que recibieron quimiorradioterapia preoperatoria. CONCLUSIONES: La anastomosis engrapada reforzada con suturas realizadas a mano dio como resultado menos complicaciones relacionadas con la anastomosis que la anastomosis coloanal suturada a mano después de la excisión total del mesorrecto por vía transanal en casos de cáncer de recto bajo; por tanto, el primero puede ser superior y debería ser el método preferido, cuando sea técnicamente posible. Consulte Video Resumen en http://links.lww.com/DCR/B749. (Traducción-Dr. Xavier Delgadillo).


Assuntos
Anastomose Cirúrgica/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Protectomia/efeitos adversos , Neoplasias Retais/cirurgia , Grampeamento Cirúrgico/efeitos adversos , Suturas/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Anastomose Cirúrgica/instrumentação , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Neoplasias Retais/patologia , Estudos Retrospectivos , Grampeamento Cirúrgico/instrumentação
6.
Sci Rep ; 11(1): 21857, 2021 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-34750473

RESUMO

Prevention of postoperative anastomotic leakage in rectal surgery is still required. This study investigated the feasibility of endoscopic hand suturing (EHS) on rectal anastomosis ex vivo. By using isolated porcine colon, we prepared ten anastomoses 6-10 cm from the virtual anus. Then, we sutured anastomoses intraluminally by EHS, which involved a continuous suturing method in 5 cases and a nodule suturing method with extra corporeal ligation in 5 cases. Completeness of suturing, number of stitches, procedure time and presence of stenosis were investigated. Furthermore, the degree of stenosis was compared between the two suturing methods. In all cases, EHS were successfully completed. The median number of stitches and procedure time was 8 and 5.8 min, respectively. Stenosis was created in all continuous suturing cases whereas none was seen in nodule suturing cases. The shortening rate was significantly greater in the continuous suturing method than in the nodule suturing method. Intraluminal reinforcement of rectal anastomosis by EHS using nodule suturing with extra corporeal ligation is feasible without stenosis, which may be helpful as a countermeasure against possible postoperative anastomotic leakage in rectal surgery.


Assuntos
Anastomose Cirúrgica/métodos , Fístula Anastomótica/prevenção & controle , Modelos Anatômicos , Reto/cirurgia , Técnicas de Sutura , Anastomose Cirúrgica/instrumentação , Animais , Endoscopia Gastrointestinal/instrumentação , Endoscopia Gastrointestinal/métodos , Estudos de Viabilidade , Humanos , Técnicas In Vitro , Modelos Animais , Proctoscopia/instrumentação , Proctoscopia/métodos , Sus scrofa , Técnicas de Sutura/instrumentação
7.
Pediatrics ; 148(5)2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34615695

RESUMO

Thoracoscopic esophageal atresia (EA) repair affords many benefits to the patient; however, intracorporeal suturing of the anastomosis is technically challenging. Esophageal magnetic compression anastomosis (EMCA) is a compelling option for endoluminal EA repair, but available EMCA devices have prohibitive rates of recalcitrant stricture. Connect-EA is a new endoluminal EMCA device system that employs 2 magnetic anchors with a unique mating geometry designed to reliably create a robust anastomosis and decrease rates of leak and stricture. We describe our first-in-human experience with this novel endoluminal device for staged EA repair in 3 patients (Gross type A, B, and C) at high risk for conventional surgical repair. First, the esophageal pouches were approximated thoracoscopically. After acute tension subsided, the device anchors were endoscopically placed in the esophageal pouches and mated. Anchors were spontaneously excreted in 2 cases. Endoscopic repositioning and retrieval of the anchors were required in 1 patient because of narrowed esophageal anatomy. There were no perioperative complications. Patients were managed for 14 to 18 months. The strictures that developed in the patients were membranous and responded well to dilation alone, resolving after 4 to 5 outpatient dilations. Gastrostomies were closed between 6 and 11 months and all patients are tolerating full oral nutrition. Early experience with this new endoluminal EMCA device system is highly favorable. The device offers considerable benefit over conventional handsewn esophageal anastomosis and anastomotic outcomes are superior to available EMCA devices.


Assuntos
Anastomose Cirúrgica/instrumentação , Atresia Esofágica/cirurgia , Imãs , Anastomose Cirúrgica/métodos , Fístula Anastomótica/prevenção & controle , Dilatação/métodos , Desenho de Equipamento , Estenose Esofágica/prevenção & controle , Esofagoscopia , Idade Gestacional , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Toracoscopia/métodos , Resultado do Tratamento
9.
World Neurosurg ; 156: 53-55, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34508907

RESUMO

OBJECTIVE: The standard way of isolating bypass vessels from surrounding structures during cerebral bypass surgery has been to use a rubber dam or neurosurgical patty. Here, the use of polyvinyl alcohol (PVA) sponges is described as a possible upgrade from these traditional bypass dams. METHODS: PVA sponges were used to isolate bypass arteries from surrounding tissues during microvascular anastomosis in 25 patients undergoing bypass surgery at our institution. RESULTS: There were no adverse events related to the use of PVA for microvascular anastomosis. PVA sponges offered some specific advantages when compared with rubber and cottonoid dams. CONCLUSIONS: Although preliminary, our experience using PVA sponges during microvascular anastomosis suggests some of their properties can facilitate cerebral bypass surgery.


Assuntos
Revascularização Cerebral/métodos , Álcool de Polivinil/administração & dosagem , Tampões de Gaze Cirúrgicos , Anastomose Cirúrgica/instrumentação , Anastomose Cirúrgica/métodos , Revascularização Cerebral/instrumentação , Humanos , Álcool de Polivinil/química
10.
Sci Rep ; 11(1): 19203, 2021 09 28.
Artigo em Inglês | MEDLINE | ID: mdl-34584186

RESUMO

We aimed to prepare a bioactive and biodegradable bilayer mesh formed by fibroblast growth factor (FGF) loaded gelatin film layer, and poly ε-caprolactone (PCL) film layer, and to investigate its treatment efficacy on esophageal anastomosis. It is envisaged that the bioactive mesh in in vivo model would improve tissue healing in rats. The full thickness semicircular defects of 0.5 × 0.5 cm2 were created in anterior walls of abdominal esophagus. The control group had abdominal esophagus isolated with distal esophageal blunt dissection, and sham group had primary anastomosis. In the test groups, the defects were covered with bilayer polymeric meshes containing FGF (5 µg/2 cm2), or not. All rats were sacrificed for histopathology investigation after 7 or 28 days of operation. The groups are coded as FGF(-)-7th day, FGF(+)-7th day, and FGF(+)-28th day, based on their content and operation day. Highest burst pressures were obtained for FGF(+)-7th day, and FGF(+)-28th day groups (p < 0.005) and decreased inflammation grades were observed. Submucosal and muscular collagen deposition scores were markedly increased in these groups compared to sham and FGF(-)-7th day groups having no FGF (p = 0.002, p = 0.001, respectively). It was proved that FGF loaded bioactive bilayer mesh provided effective repair, reinforcement and tissue healing of esophageal defects.


Assuntos
Esôfago/cirurgia , Fatores de Crescimento de Fibroblastos/administração & dosagem , Telas Cirúrgicas , Anastomose Cirúrgica/instrumentação , Animais , Plásticos Biodegradáveis , Esôfago/lesões , Gelatina , Humanos , Masculino , Modelos Animais , Poliésteres , Ratos , Cicatrização/efeitos dos fármacos
11.
Sci Rep ; 11(1): 17512, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-34471219

RESUMO

This study aimed to evaluate the biocompatibility and patency of our newly developed titanium vascular anastomotic device (TVAD) in a pig jugular vein. TVAD was made of commercially pure grade 2 titanium. The patency and anastomotic time were simultaneously confirmed in an ex-vivo system developed by the authors and in vivo using pig jugular veins. Five 8-month-old pigs, with body weights of 50-60 kg, underwent anastomosis of both jugular veins using the device. Graft patency was evaluated for 12 weeks by biplane angiography and sonography. All tissue biopsy samples were analysed by histology. In all 10 cases, the anastomosis was completed in < 5 min. The vessel lumen was not damaged, and the inner vessel wall was completely endothelialised at the anastomotic site. No foreign body reactions were observed at the vessel lumen, vessels, and outer vessel walls by histopathologic analysis. Patency and absence of leakage at the anastomotic site of the follow-up period were confirmed clearly by angiography and sonography. This preliminary animal study proved that our newly developed device is a very promising tool for intima-to-intima contact anastomosis. TVAD can be used as a feasible and safe medical tool for vessel anastomosis.


Assuntos
Anastomose Cirúrgica/instrumentação , Implante de Prótese Vascular/instrumentação , Veias Jugulares/cirurgia , Teste de Materiais/métodos , Titânio/química , Grau de Desobstrução Vascular , Anastomose Cirúrgica/métodos , Animais , Veias Jugulares/patologia , Modelos Animais , Suínos
12.
PLoS One ; 16(4): e0249418, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33793654

RESUMO

The present meta-analysis aimed to investigate the differences in the incidence of thrombosis and vascular compromise in arterial anastomosis between microvascular anastomotic devices and hand-sewn techniques during free tissue transfer in the head and neck. We searched for articles in PubMed/Medline, CNKI, WANFANG DATA, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, and Web of Science, from January 1, 1962 till April 1, 2020 that reported data of microvascular anastomosis during free tissue transfer in the head and neck. The incidence of arterial thrombosis or vascular compromise, or both was the primary outcome. The secondary outcome was anastomotic time. We also assessed the sensitivity and the risk of bias. This meta-analysis included 583 arterial anastomoses from six studies. The group using microvascular anastomotic devices tended to have an increased incidence of arterial thrombosis and vascular compromise (risk ratio (RR), 3.42; P = 0.38; 95% confidence interval (CI), 0.91-12.77). The hand-sewn technique took significantly longer to perform the anastomosis compared with that of the microvascular anastomotic devices (weighted mean difference, 15.26 min; P<0.01; 95% CI, 14.65-15.87). Microvascular anastomotic devices might increase the risk of arterial thrombosis and vascular compromise compared with the hand-sewn technique; however, further randomized controlled trials are needed to provide a more accurate estimate. The application of microvascular anastomotic devices will help to reduce anastomotic surgery time and achieve acceptable vessel opening, benefiting from the developments of arterial couplers and microsurgical techniques.


Assuntos
Anastomose Cirúrgica/métodos , Artérias/cirurgia , Anastomose Cirúrgica/efeitos adversos , Anastomose Cirúrgica/instrumentação , Bases de Dados Factuais , Retalhos de Tecido Biológico , Cabeça/cirurgia , Humanos , Pescoço/cirurgia , Risco , Trombose/etiologia , Doenças Vasculares/etiologia
14.
BMC Vet Res ; 17(1): 167, 2021 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-33858391

RESUMO

BACKGROUND: Equine small intestinal resection and anastomosis is a procedure where optimizing speed, without compromising integrity, is advantageous. There are a range of different needle holders available, but little is published on the impact surgical instrumentation has on surgical technique in veterinary medicine. The objectives of this study were to investigate if the needle holder type influences the anastomosis construction time, the anastomosis bursting pressure and whether the bursting pressure is influenced by the anastomosis construction time. Single layer end-to-end jejunojejunal anastomoses were performed on jejunal segments harvested from equine cadavers. These segments were randomly allocated to four groups. Three groups based on the needle holder type that was used: 16.5 cm Frimand (Group 1), 16 cm Mayo-Hegar (Group 2) or 20.5 cm Mayo-Hegar (Group 3) needle holders. One (Group 4) as control without anastomoses. Anastomosis construction time was recorded. Bursting pressure was determined by pumping green coloured fluid progressively into the lumen whilst recording intraluminal pressures. Maximum pressure reached prior to failure was recorded as bursting pressure. Construction times and bursting pressures were compared between needle holder, and the correlation between bursting pressure and construction time was estimated. RESULTS: Construction times were not statistically different between groups (P = 0.784). Segments from Group 2 and Group 3 burst at a statistically significantly lower pressure than those from Group 4; P = 0.031 and P = 0.001 respectively. Group 4 and Group 1 were not different (P = 0.125). The mean bursting pressure was highest in Group 4 (189 ± 61.9 mmHg), followed by Group 1 (166 ± 31 mmHg) and Group 2 (156 ± 42 mmHg), with Group 3 (139 ± 34 mmHg) having the lowest mean bursting pressure. Anastomosis construction time and bursting pressure were not correlated (P = 0.792). CONCLUSIONS: The tested needle holders had a significant effect on bursting pressure, but not on anastomosis construction time. In an experimental setting, the Frimand needle holder produced anastomoses with higher bursting pressures. Further studies are required to determine clinical implications.


Assuntos
Anastomose Cirúrgica/veterinária , Cavalos/cirurgia , Jejuno/cirurgia , Instrumentos Cirúrgicos/veterinária , Anastomose Cirúrgica/instrumentação , Animais , Feminino , Masculino , Duração da Cirurgia , Técnicas de Sutura/veterinária
15.
J Plast Reconstr Aesthet Surg ; 74(6): 1286-1302, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33551362

RESUMO

INTRODUCTION: There are several reasons microsurgeons may not use a coupler device in arterial anastomosis: may be thick-walled, non-pliable due to atherosclerotic calcification or present vessel geometrical discrepancies. This review summarises the current applications, efficacy and troubleshooting of microvascular coupler devices in arterial end-to-end anastomosis. METHODS: A systematic review of the literature was performed in November 2020 across 4 electronic databases and in accordance with the PRISMA guidelines. All studies comprised the data synthesis that reported the use of a microvascular coupler device for arterial end-to-end anastomosis. Data were extracted and collected in three groups of standardised variables: study, anastomosis-related and technical characteristics. RESULTS: Out of the 7,690 articles identified, 20 were included in the final data synthesis. Included studies involved a total of 1639 patients, who underwent 670 arterial and 1,124 venous anastomoses. Out of all arterial anastomoses, 351 were performed in free tissue transfers in head and neck, 117 in breast, 4 in upper extremity and 5 in lower extremity reconstruction, whereas the remaining were not specified. The total arterial coupler anastomosis success rate reported was 92.1% (617/670). Fifty-three (8%) arterial anastomoses were reported to result in either troubleshooting events or intra- or post-operative failures, most being reported in extremity reconstructions. CONCLUSIONS: Arterial coupling is not widespread with predominant use in head and neck and chest reconstructions, and total reported efficacy of 92.1%. Microsurgeons are reluctant to routinely use current widespread coupler devices as a result of inherent arterial characteristics. This study delivered collective recommendations, 'do's and don'ts' of microvascular arterial coupling.


Assuntos
Artérias/cirurgia , Procedimentos de Cirurgia Plástica , Procedimentos Cirúrgicos Vasculares , Anastomose Cirúrgica/instrumentação , Anastomose Cirúrgica/métodos , Retalhos de Tecido Biológico , Humanos , Microvasos/cirurgia , Utilização de Procedimentos e Técnicas/estatística & dados numéricos , Procedimentos de Cirurgia Plástica/efeitos adversos , Procedimentos de Cirurgia Plástica/instrumentação , Procedimentos de Cirurgia Plástica/métodos , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Procedimentos Cirúrgicos Vasculares/instrumentação , Procedimentos Cirúrgicos Vasculares/métodos
16.
BMC Surg ; 21(1): 47, 2021 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-33478457

RESUMO

BACKGROUND: Recently, due to increasing reports of stenosis after esophagojejunostomy created using circular staplers and a transorally inserted anvil (OrVil™) following laparoscopic proximal gastrectomy (LPG) and total gastrectomy (LTG), linear staplers are being used instead. We investigated our preventive procedure for esophagojejunostomy stenosis following use of circular staplers. METHODS: Since the anastomotic stenosis is considered to be mainly caused by tension in the esophageal and jejunal stumps at the anastomotic site, we have been performing procedures to relieve this tension, by cutting off the rubber band and pushing the shaft of the circular stapler toward the esophageal side, since July 2015. We retrospectively compared the incidence of anastomotic stenosis in cases of LPG and LTG performed before July 2015 (early phase, 30 cases) versus those performed after this period (later phase, 22 cases). RESULTS: Comparison of the incidence of anastomotic stenosis according to the type of surgery, LPG or LTG, and between the two time periods versus all cases, indicated a significantly lower incidence in the later phase than in the early phase (4.5 vs. 26.7%, p < 0.05), especially for LPG (0 vs. 38.5%, p < 0.05). CONCLUSIONS: It is possible to use a circular stapler during laparoscopic esophagojejunostomy, as with open surgery, if steps to reduce tension on the anastomotic site are undertaken. These procedures will contribute to the spread of safe and simple laparoscopic anastomotic techniques.


Assuntos
Anastomose Cirúrgica/efeitos adversos , Anastomose Cirúrgica/métodos , Constrição Patológica/prevenção & controle , Esôfago/cirurgia , Jejuno/cirurgia , Neoplasias Gástricas , Idoso , Anastomose Cirúrgica/instrumentação , Constrição Patológica/etiologia , Feminino , Gastrectomia/efeitos adversos , Gastrectomia/métodos , Humanos , Laparoscopia/efeitos adversos , Laparoscopia/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Neoplasias Gástricas/cirurgia , Grampeamento Cirúrgico/instrumentação , Grampeamento Cirúrgico/métodos
17.
Zhonghua Wei Chang Wai Ke Za Zhi ; 24(1): 35-42, 2021 Jan 25.
Artigo em Chinês | MEDLINE | ID: mdl-33461250

RESUMO

In the past 30 years, minimally invasive surgery has been greatly improved with the development of the energy platform, instrument platform, and imaging platform. Taking colorectal cancer surgery as an example, the five elements of surgical procedure have developed to a certain extent. The surgical approach has undergone a process from large to small. The range of resection ranges from simple bowel resection to radical resection/extended radical resection, and then to surgery that focuses on preserving organ function. With the recognition of the direction of normal lymphatic drainage and the characteristics of tumor lymphatic metastasis, lymph node dissection has been gradually standardized. The reconstruction of the digestive tract has changed from manual sutures to full endoscopic anastomosis, and then to the concept of functional anastomosis. The removal of the specimen has improved from large incision through the abdominal wall, to small laparoscopic incision, and then to the natural cavity. The evolution of these procedures depends on the advancement of technology platforms and equipment, and the recognition of new concepts. The development of minimally invasive platform must be in the direction of ensuring the implementation of the most optimized surgical approach. The platform is more secure, integrated, multifunctional, and intelligent. In the future, minimally invasive procedures must be aimed at maximizing the benefits of patients. The procedures are more scientific, functional, comfortable and diverse. Surgical innovation has promoted the development of the platform. The platform and the surgical procedure promote each other's development.


Assuntos
Neoplasias Colorretais/cirurgia , Procedimentos Cirúrgicos do Sistema Digestório , Laparoscopia , Procedimentos Cirúrgicos Minimamente Invasivos/tendências , Anastomose Cirúrgica/instrumentação , Anastomose Cirúrgica/métodos , Anastomose Cirúrgica/tendências , Neoplasias Colorretais/patologia , Procedimentos Cirúrgicos do Sistema Digestório/instrumentação , Procedimentos Cirúrgicos do Sistema Digestório/métodos , Procedimentos Cirúrgicos do Sistema Digestório/tendências , Previsões , Humanos , Laparoscopia/instrumentação , Laparoscopia/métodos , Laparoscopia/tendências , Excisão de Linfonodo , Metástase Linfática , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Técnicas de Sutura/instrumentação , Técnicas de Sutura/tendências
18.
J Surg Res ; 258: 200-212, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33035743

RESUMO

BACKGROUND: To minimize complications associated with the construction of the hand-sewn aortic anastomosis, alternative experimental methods have been pursued. This study aimed to evaluate the efficacy of experimental anastomotic devices in relation to time and point of rupture of the anastomosis in comparison to the conventional technique. MATERIALS AND METHODS: An electronic search was performed using MEDLINE, Scopus, Science Direct, and Cochrane Library databases by two independent authors. Our exclusion criteria referred to studies reporting results solely from end-to-side anastomosis, results on vessels other than the aorta, studies that did not involve animal experiments, and non-English publications. The last search date was January 1, 2020. RESULTS: The meta-analysis included 22 studies with 34 anastomosis samples and a total of 316 animals. The pooled mean automated anastomosis time was 10.38 min, and the mean point of rupture was 32.7 N. In the subgroup analysis of automated anastomosis time by device category, the anastomotic stenting technique reported significantly lower anastomosis time but also showed significantly lower point of rupture. Comparing the efficacy of experimental devices and the hand-sewn technique, our pooled analysis showed that automated devices significantly decrease the time needed to perform the anastomosis (weighted mean difference -7.24 min). On the other hand, the automated anastomosis is also associated with decreased tensile strength (weighted mean difference -20.68 N). CONCLUSIONS: Although experimental devices seem to offer a faster anastomosis, they lack endurance when compared with the hand-sewn technique. Further research is needed for the development of an "ideal" anastomotic technique.


Assuntos
Anastomose Cirúrgica/instrumentação , Aorta/cirurgia , Anastomose Cirúrgica/estatística & dados numéricos , Animais , Técnicas de Sutura , Fatores de Tempo
19.
Ann Thorac Surg ; 111(6): 1909-1915, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33065052

RESUMO

BACKGROUND: We recently reported early postoperative results comparing the use of an anastomosis-assist device with a side-biting clamp for ascending aorta during coronary artery bypass grafting (CABG). Transient neurological complications occurred less often with the device. Here, we evaluated the perioperative safety of the device compared with the aorta no-touch technique (no-touch). METHODS: We evaluated patients listed in the Japan Adult Cardiovascular Surgery Database who received isolated off-pump CABG with either the device or the no-touch approach from 2014 to 2016. We performed a one-to-one matched analysis based on a propensity score modeled from patient demographics, comorbidities, cardiac conditions, and procedural characteristics. We compared early outcomes in both groups using Pearson's chi-square or Wilcoxon rank sum test as appropriate; P less than .05 was statistically significant. RESULTS: Among 9546 device and 6890 no-touch patients, we found 5012 patient matches for each group. The device operation time was significantly longer (293 versus 281 minutes; P < .001) and homologous transfusion was significantly greater (56.9% versus 51.0%; P < .001) than with no-touch. Thirty-day operative mortality (1.5% versus 1.7%; P = .34), morbidity and mortality (6.8% versus 7.5%; P = .17), and stroke (0.9% versus 1.1%; P = .36) were similar in both groups. New-onset atrial fibrillation (11.9% versus 10.3%; P = .01) occurred significantly more often with the device. Newly initiated dialysis (1.4% versus 1.9%; P = .051) was more frequent with no-touch whereas reoperation for graft occlusion was more frequent with the device (1.0% versus 0.6%; P = .06) but was not significant for either outcome. CONCLUSIONS: The clinical safety of use of the device in CABG was comparable to no-touch for mortality and morbidity. Hemostasis may be a key issue for accomplishing higher-level quality control when devices are used in proximal anastomosis of CABG.


Assuntos
Aorta/cirurgia , Ponte de Artéria Coronária sem Circulação Extracorpórea/instrumentação , Doença da Artéria Coronariana/cirurgia , Complicações Pós-Operatórias/epidemiologia , Idoso , Anastomose Cirúrgica/efeitos adversos , Anastomose Cirúrgica/instrumentação , Ponte de Artéria Coronária sem Circulação Extracorpórea/efeitos adversos , Bases de Dados Factuais , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
20.
Surg Today ; 51(4): 575-581, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32974752

RESUMO

PURPOSE: Using a circular stapler to create an anastomosis for esophagogastrostomy after esophagectomy is well accepted; however, it remains uncertain if the greater curvature (GC) or lesser curvature (LC) of the gastric conduit is better for the anastomosis. We conducted this prospective study to compare the integrity of esophagogastrostomy between the esophagus and the GC or LC side of the gastric conduit. METHODS: The subjects of this study were 70 patients who underwent esophagectomy and were randomized to a "GC" group and an "LC" group (n = 35 each). The primary and secondary end points were anastomotic leakage (AL) and anastomotic stricture (AS), respectively. RESULTS: The overall AL rate was 22.1%, without a significant difference between the groups. Stump leakage developed in eight of nine patients in the GC group, whereas leakage developed at the esophagogastric anastomosis in five of six patients in the LC group. The rate of stump leakage was significantly higher than that of esophagogastric AL in the GC group. The overall AS rate was 4.4%, with a significant difference between the groups (0% in the GC group vs. 9.1% in the LC group). CONCLUSIONS: AL rates were comparable in the two groups, but the sites of leakage were significantly different.


Assuntos
Neoplasias Esofágicas/cirurgia , Esofagectomia/métodos , Esôfago/cirurgia , Gastrostomia/métodos , Grampeadores Cirúrgicos , Grampeamento Cirúrgico/instrumentação , Anastomose Cirúrgica/instrumentação , Anastomose Cirúrgica/métodos , Fístula Anastomótica/epidemiologia , Fístula Anastomótica/etiologia , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Grampeadores Cirúrgicos/efeitos adversos , Grampeamento Cirúrgico/efeitos adversos , Grampeamento Cirúrgico/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...